Today’s SCADA/Telemetry
systems require the transport of large
amounts of data at ever-increasing
speeds. Additionally, the need for
greater packaging flexibility has
redefined the “ideal” wireless platform
in many applications. MDS is pleased to
introduce MDS TransNET™ a flexible, high
speed, compact license-free wireless
solution.
Product Overview
The MDS TransNET utilizes FHSS
(Frequency Hopping Spread Spectrum) in
the ISM Band of 902 – 928 MHz to provide
reliable long range data transportation
at up to 115.2 kbps. The TransNET
provides transparent data communications
for nearly all SCADA/Telemetry and EFM
protocols including MODBUS.
Any MDS TransNET may be configured as a
repeater extension. This allows store
and forward data operation to extend the
operating range of the network. Mulitple
repeaters may exist at any level of the
network preventing a single radio
failure from disabling the entire
network. There is no limit to the number
of repeaters which may be used. This
product is available for use in Class 1,
Division 2, Groups A, B, C & D hazardous
locations.*
Why consider an MDS TransNET™ solution?
High system
performance and data integrity!
Robust construction, digital signal
processing (DSP) technology with
self-equalization, automatic CRC/ARQ and
powerful forward error correction.
Flexibility and rapid
installation! Quick return on
investment due to plug-and-play
installation. License-free radio design
with the ability to communicate with any
asynchronous protocol without extra
software or additional programming.
Performance under the most
adverse conditions! Robust
design provides excellent performance in
the face of interference or difficult
signal paths.
Small footprint!
Exceptionally small design allows
installation inside RTU or PLC housing.
MDS network-wide diagnostics
software simplifies tasks and
reduces the cost of managing the network
infrastructure by eliminating trips to
the field. Provides a non-intrusive
means of maintaining link and radio
network performance.
Flexible interfaces!
All TransNETs come equipped with RS-232
for direct connection to most RTU/PLC’s
and RS-485 for multidrop environments.
Low Power Consumption!
Sleep mode for extremely low power
consumption requirements - typically
draws 7 mA - yet still recovers quickly
for fast access to your critical data.
MDS TransNET is the
price/performance leader;
offering flexibility and reliability for
both point-to-point and point-to-mulitpoint
requirements.
More Information
Click
here to download the latest Adobe Acrobat
Reader.
Features
-
High Speed Throughput – 115.2
Kbps
-
Unparalleled Robustness –
Forward error correction, CRC/ARQ, multiple
resends
-
Industrial grade – Extended -40°
C to +70° C temperature range for trouble free
operation in extreme environments
-
Sleep Mode – ~ 7mA, ideal for
solar power applications
-
Store and Forward - with
self-healing networks
-
Network wide diagnostics –
Central network control without the need to
visit sites
Specifications
Data Characteristics
|
Transmitter |
Receiver |
Connectors |
Environmental |
Physical |
Operating Modes |
Network Management |
Agency Approvals |
Configuration Diagrams
Interface:
RS-232/RS-485 (User Selectable)
Usable
Throughput:
115.2
kbps
Port
Speed:
1.2 to
115.2 kbps
Power
Output:
1 Watt
(30 dBm) at 6Vdc to 30 Vdc, user
selectable down to 100 mw (+20 dBm)
Modulation:
CPFSK
Sensitivity:
-108 dBm
(1 x 10-6 BER) typical
Error
Detection:
CRC16;
Resend on Error
Interference Avoidance:
64,000
hop patterns selected automatically via
network address
FEC, CRC/ARQ
and/or Multiple Packet Transmits
Excellent
Strong Signal (interference)
Characteristics
Band
Segmentation for Friendly Coexistence
with Other Services such as LMS
Power and
User:
2 Pin
Phoenix, DB-9, RJ11
RF:
TNC
Humidity:
< 95% RH
(Non-Condensing)
Temperature Range:
-40° C to
+70° C
Current
Consumption:
Mode
30 Vdc
13.8 Vdc
6
Vdc




Transmit
236 mA
510 mA
1.18 A
Receive
51 mA
100 mA
155 mA
Sleep
Mode :
7 mA
typical
Input
Power:
6 to 30
Vdc
Dimensions:
(approx.
3.5 D x 5 W x 1 H inches)
(approx. 8.9 D x 12.7 W x 2.5 H cm)
Point-to-Point:
Full
Duplex (57.6 kbps) TDD
Point-to-Multipoint:
Master
Remote
Repeater Extension (Store-and Forward) -
Unlimited Repeaters; Self-healing
Networks
Diagnostics
Centralized network control eliminates
site visits
Create store-and-forward configurations
Compatible with Other MDS Products
MDS InSite
FCC:
Part 15
Approved
UL/CSA:
Class 1
Div. 2 approved* (UL 508, UL 1604)
IC:
Approved

* The transceiver is not
acceptable as a stand-alone unit for use in the
hazardous locations described above. It must
either be mounted within another piece of
equipment, which is certified for hazerdous
locations, or installed within guidelines, or
conditions of approval, as set forth by
approving agencies.
MDS products
are manufactured under a quality system
certified to ISO 9001. MDS reserves the right to
make changes to specifications of products
described in this data sheet at any time without
notice and without obligation to notify any
person of such changes.
Copyright 2001
MDS Inc. (MDS TransNET) SL0094 Rev. N, 07-29-03
-
High Speed Throughput – 115.2 Kbps
Unparalleled Robustness – Forward error correction, CRC/ARQ, multiple resends
Industrial grade – Extended -40° C to +70° C temperature range for trouble free operation in extreme environments
Sleep Mode – ~ 7mA, ideal for solar power applications
Store and Forward - with self-healing networks
Network wide diagnostics – Central network control without the need to visit sites
Specifications
|
|
|
Data Characteristics | Transmitter | Receiver | Connectors | Environmental | Physical | Operating Modes | Network Management | Agency Approvals | Configuration Diagrams |
|
|
|||||||||||||||||
|
Interface: |
RS-232/RS-485 (User Selectable) |
||||||||||||||||
|
|
|||||||||||||||||
|
Usable Throughput: |
115.2 kbps |
||||||||||||||||
|
|
|||||||||||||||||
|
Port Speed: |
1.2 to 115.2 kbps |
||||||||||||||||
|
|
|||||||||||||||||
|
Power Output: |
1 Watt
(30 dBm) at 6Vdc to 30 Vdc, user
selectable down to 100 mw (+20 dBm) |
||||||||||||||||
|
|
|||||||||||||||||
|
Modulation: |
CPFSK |
||||||||||||||||
|
|
|||||||||||||||||
|
Sensitivity: |
-108 dBm (1 x 10-6 BER) typical |
||||||||||||||||
|
|
|||||||||||||||||
|
Error Detection: |
CRC16; Resend on Error |
||||||||||||||||
|
|
|||||||||||||||||
|
Interference Avoidance: |
64,000
hop patterns selected automatically via
network address FEC, CRC/ARQ
and/or Multiple Packet Transmits Excellent
Strong Signal (interference)
Characteristics Band Segmentation for Friendly Coexistence with Other Services such as LMS |
||||||||||||||||
|
|
|||||||||||||||||
|
Power and User: |
2 Pin Phoenix, DB-9, RJ11 |
||||||||||||||||
|
|
|||||||||||||||||
|
RF: |
TNC |
||||||||||||||||
|
|
|||||||||||||||||
|
Humidity: |
< 95% RH (Non-Condensing) |
||||||||||||||||
|
|
|||||||||||||||||
|
Temperature Range: |
-40° C to +70° C |
||||||||||||||||
|
|
|||||||||||||||||
|
Current Consumption: |
|
||||||||||||||||
|
|
|||||||||||||||||
|
Sleep Mode : |
7 mA typical |
||||||||||||||||
|
|
|||||||||||||||||
|
Input Power: |
6 to 30 Vdc |
||||||||||||||||
|
|
|||||||||||||||||
|
Dimensions: |
(approx.
3.5 D x 5 W x 1 H inches) |
||||||||||||||||
|
|
|||||||||||||||||
|
Point-to-Point: |
Full Duplex (57.6 kbps) TDD |
||||||||||||||||
|
|
|||||||||||||||||
|
Point-to-Multipoint: |
Master
|
||||||||||||||||
|
|
|||||||||||||||||
|
|
Diagnostics |
||||||||||||||||
|
|
|||||||||||||||||
|
FCC: |
Part 15 Approved |
||||||||||||||||
|
|
|||||||||||||||||
|
UL/CSA: |
Class 1 Div. 2 approved* (UL 508, UL 1604) |
||||||||||||||||
|
|
|||||||||||||||||
|
IC: |
Approved |
||||||||||||||||
|
|
|||||||||||||||||
|
|
|
||||||||||||||||
|
|
|||||||||||||||||
* The transceiver is not acceptable as a stand-alone unit for use in the hazardous locations described above. It must either be mounted within another piece of equipment, which is certified for hazerdous locations, or installed within guidelines, or conditions of approval, as set forth by approving agencies.
MDS products are manufactured under a quality system certified to ISO 9001. MDS reserves the right to make changes to specifications of products described in this data sheet at any time without notice and without obligation to notify any person of such changes.
Copyright 2001 MDS Inc. (MDS TransNET) SL0094 Rev. N, 07-29-03