OVERVIEW
The DOC4D is a four input alarm notification device that utilizes the digital control channel on the Cellemetry network to transport remote alarm conditions directly to you on a report-by-exception basis. The configurability of the device allows it to be "tuned" to accept erratic inputs and assures compatibility with most alarming requirements.

The eLynx web site provides access to interface with the device. A customer specific login allows administration of the alarm notification lists, as well as a window into the alarm history of each activated input. When the DOC4D is configured to notify on a transition to normal state as well as an alarm transition, the interface can be set to calculate duration of alarm state. This has shown to be useful for certain types of analysis, with the most common being the representation of compressor runtime percentages.
   
FEATURES
  • Instantaneous exception based alarming
  • Configurable for notify on alarm only, or notify on alarm and return to normal
  • Control via the Internet
  • Cost efficient pricing
  • Minimal power requirements
  • Tunable debounce on a per input basis
  • Easy installation

BENEFITS

  • Wireless communications utilizing existing infrastructure (no need to install towers, phone lines, obtain radio licenses, etc.)
  • Coverage throughout the U.S., Canada, Mexico, and parts of South America
  • Low cost of ownership
  • Dependable service

SPECIFICATIONS
PHYSICAL
Size: 6.25" L x 3.25" x 1.5" H
Weight: < 1.0 lb.
Lights: 1 LED with blink patterns to indicate
   Power
   Alarm
   Signal
   Registration
Connectors: Power - Phoenix PCB
  D/Is 1 - 4 Phoenix PCB
Programming - 1/8", 3 conductor phono tip
  Radio - SMA Female
Temperature: -30 C to +60 C

ELECTRICAL

Input voltage 8 - 24 VDC
Idle current 70 micro amps
Active input current 2.4 milliamps
Instantaneous tx 1500 milliamps

PRINCIPLE OF OPERATION

The DOC4D uses the existing cellular infrastructure, in particular the digital overhead control channel, to transport alarm and status changes. Since the more robust, control channel portion of the network is used; actual coverage exceeds that of the voice side.

The alarm messages are received at eLynx's central data facility through a secure connection. A specific ten-digit number embedded in each message identifies the customer, device name, and location. The status of each of the four inputs is also contained in the message. A comparison is made to determine which input(s) are in alarm, and appropriate notifications are delivered to the customer's e-mail, alphanumeric pager, or text messaging cell phone.

TYPICAL APPLICATIONS

  • Compressor shut down
  • Tank level alarm
  • Valve position
  • Dehydrator low temp alarm
  • Intrusion detection
  • High or low pressure alarms
  • Loss of commercial power
  • Low flow alarm